Towards high-accuracy mass spectrometry of highly charged short-lived ions at ISOLTRAP
2006
Dedicated to H.-J. Kluge on the occasion of his 65th birthday anniversary - Jürgen Kluge Special Issue; Multiply charged ions of stable xenon isotopes from a plasma ion source have been mass-selected by the on-line mass separator ISOLDE/CERN and delivered to the triple-trap mass spectrometer ISOLTRAP. The doubly charged ions that survived the charge-exchange processes during bunching and ion preparation were transferred to a precision Penning trap for mass determination. Mass values were obtained for the isotopes with mass numbers A=126,129,130,136. They are consistent with previous results except for the case of $^{126}Xe$ where a significant deviation from the literature value was found. …
Nuts and dried fruits: Natural occurrence of emerging Fusarium mycotoxins
2013
Abstract The occurrence of enniatins (ENs) and beauvericin (BEA) in nuts, dried fruits and dates available in Valencia (Spain) was surveyed in this study. To do this, seventy-four samples of nuts, dried fruits and dates were analyzed for the determination of mycotoxin contamination. Mycotoxins were identified and quantified using an ultrasonic-C18 extraction and LC–MS/MS with a triple quadrupole (QqQ) mass analyzer. The frequencies of contamination of nuts, shell, dried fruits and dates were 50%, 80%, 35.7% and 83.3%, respectively. Enniatin A (ENA) was the most predominant EN found in nuts (45.2%) while ENB was the most common EN found in dates (58.3%). The analytical results of the shell s…
A compact apparatus for mass selective resonance ionization spectroscopy in a buffer gas cell
1997
Abstract An ultra-sensitive laser spectroscopic method for the investigation of transuranium nuclides has been developed based on resonance ionization in an argon buffer gas cell. This method has been combined with ion-guide extraction and mass selective direct detection of the resonantly ionized atoms. Using argon as a buffer gas, recoils of fusion reactions can be thermalized even at low pressure. The differential pumping system consists of only one roots pump and two turbo molecular pumps. The set-up has been tested with 243 Am evaporated from a filament located inside the optical gas cell. Resonance ionization is performed using a two-step excitation with an excimer-dye-laser combinatio…
Quadrupole interaction of $^{8}$Li and $^{9}$Li in LiNbO$_{3}$ and the quadrupole moment of $^{9}$Li
1988
The quadrupole interaction of nuclear spin polarized8Li (I=2) and9Li (I=3/2) in LiNbO3 has been studied at room temperature. The polarization was achieved by optical pumping of a fast atomic beam with circularly polarized laser light. The atoms were implanted into a hexagonal LiNbO3 single crystal and the quadrupole splitting ofβ-NMR spectra was measured. A ratio of ¦Q(9Li)/Q(8Li)¦=0.88(4) for the nuclear quadrupole moments was deduced, yielding a new value of ¦Q(9Li)¦=25.3 (9) mb for the quadrupole moment of9Li.
Mass measurements on neutron-deficient Sr and neutron-rich Sn isotopes with the ISOLTRAP mass spectrometer
2005
Abstract The atomic masses of 76,77,80,81,86,88 Sr and 124,129,130,131,132 Sn were measured by means of the Penning trap mass spectrometer ISOLTRAP at ISOLDE/CERN. 76 Sr is now the heaviest N = Z nucleus for which the mass is measured to a precision better than 35 keV. For the tin isotopes in the close vicinity of the doubly magic nucleus 132 Sn, mass uncertainties below 20 keV were achieved. An atomic mass evaluation was carried out taking other experimental mass values into account by performing a least-squares adjustment. Some discrepancies between older experimental values and the ones reported here emerged and were resolved. The results of the new adjustment and their impact will be pr…
Direct mass measurements of neutron-deficient xenon isotopes with the ISOLTRAP mass spectrometer
2000
Abstract The masses of Xe isotopes with 124⩾ A ⩾114 have been measured using the ISOLTRAP spectrometer at the on-line mass separator ISOLDE/CERN. A mass resolving power of 500 000 was chosen resulting in an accuracy of δm ≈12 keV for all isotopes investigated. Conflicts with existing mass data of several standard deviations were found.
Quadrupole excitation of stored ion motion at the true cyclotron frequency
1995
Abstract The motion of an ion in a Penning trap has been investigated in the presence of an azimuthal quadrupole radio frequency field and a damping force provided by buffer gas collisions. Analytical expressions are derived which describe the line shape of the cyclotron resonance as well as the properties of the mass-selective cooling mechanism for heavy ions. Excellent agreement is observed between theoretical results and experimental data obtained with the tandem Penning trap mass spectromer ISOLTRAP at ISOLDE (CERN).
Ramsey technique applied in a Penning trap mass spectrometer
1991
Abstract The Ramsey method has been applied in an experiment aiming for accurate mass determination of unstable isotopes. The ion motion in a Penning trap has been excited with time-separated oscillatory fields and Ramsey fringes were observed in the case of dipole and quadrupole excitation. The experimental resonances are in good agreement with theory. Further applications of the technique are discussed.
Lead speciation in rainwater samples by modified fused silica capillaries coupled to a direct injection nebulizer (DIN) for sample introduction in IC…
2001
Lead speciation using modified silica capillaries for the introduction of liquid samples to a direct injection nebulizer of an inductively coupled plasma quadrupole mass spectrometer is described and demonstrated. The fused silica capillaries were coated by covalently bonding a cation exchange active organic molecule to the activated capillary surface. The best results were obtained by introducing a bifunctional reagent in a prior step. In this case, a silane reagent was chosen which acted as a methacrylic acid group for further binding. The influence of the chemical modification of the surface of the sample capillary of the DIN on the selective retention of inorganic lead (Pb2+) and trieth…
The squeezer ion guide
1992
Abstract The properties of an ordinary ion guide can be improved by inserting a grid between the nozzle and the skimmer. When positive ions are transported, an electric potential lower than +10 V is connected to the grid and one of the order of − 10 V to the skimmer. Efficient focusing is achieved between the nozzle and the grid by a combined action of the viscous helium flow field and the weak electric field. The focusing device is called a “squeezer”. It can be extended by adding more grids, a second skimmer, and differential pumping. Contrary to the first grid, the additional elements act more or less like electrostatic lenses in medium vacuum. With the squeezer ion guide, ions created i…